Torpedo Launching Air Panel

Part Number (s): NA36057/2
Weight:
Product Code: 
CP76
Bulkhead mounted, compact, Single stage reducing panel offers robust, reliable supply of air for torpedo launching. Valves are panel mounted, either surface mounted or through panel mounted and are easily removed for maintenance.
Features: 
Inlet connection. Single stage pressure reduction. Panel mounted valves. Inlet isolation stop valve. Inlet filter. Inlet pressure gauge. Inlet pressure gauge stop & release valve. Inlet pressure vent. Dome-loaded pressure controller. Outlet pressure vent valve. Outlet pressure gauge. Outlet pressure gauge stop & release valve. Outlet relief valve. Outlet connection.
Benefits: 
Bulkhead mounted, compact, Single stage reducing panel offers robust, reliable supply of air for torpedo launching. Valves are panel mounted, either surface mounted or through panel mounted and are easily removed for maintenance.

Specification

Inlet Connection: 
tba
Outlet Connection: 
tba
Maximum Working Pressure - bar : 
tba
Maximum Working Pressure - psig: 
tba
Outlet Pressure Range - bar: 
1 - 300
Outlet Pressure Range - psi: 
1 - 4,500
Set pressure range bar: 
tba
Set pressure range psi: 
tba
Stage One Pressure Range - bar - fluid: 
tba
Stage One Pressure Range - psi - fluid: 
tba
Stage Two Pressure Range - bar - fluid : 
tba
Stage Two Pressure Range - psi - fluid: 
tba
Relief Valve Set pressure range bar: 
tba
Relief Valve Set pressure range psi: 
tba
Relief Valve Reseat Pressure %: 
11
Lift Pressure - bar: 
tba
Lift Pressure - psi: 
tba
Relief Valve Set Pressure Variation % : 
5
Filtration level - Micron : 
20
Inlet/Outlet Pressure variation (%): 
5
Medium: 
Compressed Air

Options

Limit Stop of Outlet Pressure: 
Yes
Standard Materials: 
Mild steel painted or Stainless steel panel. Nickel Aluminium Bronze valve bodies. Stainless steel valve components. Stainless steel pipe-work with stainless steel compression fittings.
Ordering Information: 
Volume & pressure of air storage reservoir. Distance of air reservoir from panel. Inlet pipe size. Inlet connection type & size. Inlet pressure range (max & min). Is inlet air isolated at panel or upstream? Outlet pressure range (max & min). Outlet pressure relief valve set pressure. Outlet pressure connection type & size. Outlet flow. Outlet pipe size. Is outlet air isolated at panel or downstream? Operating temperature range (max & min). Operating air humidity (%). Distance of torpedo launcher from panel.
Certification
Certification: 
Classification Society e.g. LRS, GL, BV, et al
Service instruction reference: 
tba
Relief Port Connection(s): 
tba
Ordering
Spares kit number: 
tba