High Pressure to Low Pressure Reducing Station (276 - 7 bar)

Part Number (s): N53747
Weight: 78 kg
Product Code: 
NGRS3000 Mk2
Monobloc, compact, Single stage reducing station offers robust, reliable supply of low pressure air. Cartridge valves allow easy maintenance by removal and replacement of valve inserts.
Features: 
Inlet connection. Inlet isolation stop valve. Inlet filter. Inlet pressure vent. Dome-loaded pressure controller. Single stage pressure reduction. Cartridge type valves. Outlet Auto shutdown valve. Outlet relief valve. Outlet pressure gauge. Outlet pressure gauge stop & release valve. Outlet connection.
Benefits: 
Monobloc, compact, Single stage reducing station offers robust, reliable supply of low pressure air. Cartridge valves allow easy maintenance by removal and replacement of valve inserts.

Specification

Inlet Connection: 
tba
Outlet Connection: 
tba
Maximum Working Pressure - bar : 
276
Maximum Working Pressure - psig: 
4000
Outlet Pressure Range - bar: 
7.5 - 276
Outlet Pressure Range - psi: 
100 - 4,000
Set pressure range bar: 
276 - 170
Set pressure range psi: 
4,000 - 2,465
Stage One Pressure Range - bar - fluid: 
276 - 7.0
Stage One Pressure Range - psi - fluid: 
4,000 - 100
Relief Valve Set pressure range bar: 
tba
Relief Valve Set pressure range psi: 
tba
Relief Valve Reseat Pressure %: 
10
Lift Pressure - bar: 
tba
Lift Pressure - psi: 
tba
Relief Valve Set Pressure Variation % : 
5
Nominal bore - mm: 
tba
Flow Factor/ Cv: 
tba
Filtration level - Micron : 
20
Inlet/Outlet Pressure variation (%): 
5
Medium: 
Compressed Air
Standard Materials: 
Nickel Aluminium Bronze manifold and valve bodies. Stainless steel valve components.
Ordering Information: 
Volume & pressure of air storage reservoir. Distance of air reservoir from manifold. Inlet pipe size. Inlet connection type & size. Inlet pressure range (max & min). Is inlet air isolated at manifold or upstream? Outlet pressure range (max & min). Outlet pressure relief valve set pressure. Outlet pressure connection type & size. Outlet flow. Outlet pipe size. Is outlet air isolated at manifold or downstream? Operating temperature range (max & min). Operating air humidity (%). Distance of low pressure air application from manifold.
Certification
Certification: 
Classification Society e.g. LRS, GL, BV, et al
CTE Test report: 
-
BAM test report: 
-
Service instruction reference: 
tba
Installation Dimensions
Height (mm): 
252
Depth (mm): 
180
Width (mm): 
429
Length of manifold (mm): 
430
Length between ports (mm): 
tba
Handle diameter (mm): 
tba
Height of port from base (mm): 
tba
Relief Port Connection(s): 
tba
Packaging Dimensions
Packaging Height (mm): 
tba
Packaging Width (mm): 
tba
Packaging Depth (mm): 
tba
Ordering
Spares kit number: 
tba