Diesel Generator Start Reducing Station
Part Number (s): NA53747/1
Weight:
Product Code:
NGRS3000 Mk2 Monobloc, compact, Single stage reducing station offers robust, reliable supply of starting air. Auto shutdown valve protects air start turbine from damage and allows a relatively small outlet pressure relief valve to be used. Cartridge valves allow easy maintenance by removal and replacement of valve inserts.
Features:
Inlet connection. Single stage pressure reduction. Cartridge type valves. Inlet isolation stop valve. Inlet filter. Inlet pressure gauge. Inlet pressure gauge stop & release valve. Inlet pressure vent. Dome-loaded pressure controller. Outlet pressure vent valve. Outlet pressure gauge. Outlet pressure gauge stop & release valve. Bypass isolation stop valve. Outlet Auto shutdown valve. Outlet relief valve. Outlet connection. Benefits:
Monobloc, compact, Single stage reducing station offers robust, reliable supply of starting air. Auto shutdown valve protects air start turbine from damage and allows a relatively small outlet pressure relief valve to be used. Cartridge valves allow easy maintenance by removal and replacement of valve inserts. Specification
Inlet Connection:
tba Outlet Connection:
tba Maximum Working Pressure - psig:
tba Outlet Pressure Range - psi:
0 - 4,500 Set pressure range psi:
tba Stage One Pressure Range - psi - fluid:
tba Stage Two Pressure Range - psi - fluid:
tba Priority Valve Reseat Pressure psig:
tba Relief Valve Set pressure range psi:
tba Relief Valve Reseat Pressure %:
10 Lift Pressure - psi:
tba Relief Valve Set Pressure Variation % :
5 Nominal bore - mm:
tba Flow Factor/ Cv:
tba Filtration level - Micron :
20 Inlet/Outlet Pressure variation (%):
5 Medium:
Compressed Air Standard Materials:
Nickel Aluminium Bronze manifold and valve bodies. Stainless steel valve components. Ordering Information:
Volume & pressure of air storage reservoir. Distance of air reservoir from manifold. Inlet pipe size. Inlet connection type & size. Inlet pressure range (max & min). Is inlet air isolated at manifold or upstream? Outlet pressure range (max & min). Auto shutdown valve set pressure. Outlet pressure relief valve set pressure. Outlet pressure connection type & size. Outlet flow. Outlet pipe size. Is outlet air isolated at manifold or downstream? Number of starts. per minute? Starting air duration per start. Operating temperature range (max & min). Operating air humidity (%). Distance of air start turbine from manifold. Service instruction reference:
tba Relief Port Connection(s):
tba